Laser Ablation

CETAC Iridia Laser Ablation System

Patented Cobalt Cell for proven <1ms to >1s flexible analytical performance

Custom 193nm 500Hz ultra-short pulse, compact, water-cooled excimer laser

2 billion shots guaranteed, 4 billion shots typical

Spot sizes from 1um - 210um

Patented eQC energy measurement at the sample surface

Patented ExiCheck gas exchange module automatically exchanges the ArF gas on a pre-set interval with no user interaction required

Geo and Bio configuration – or both!

Dual attenuators available for low energy stability (1 – 0.01 Jcm2) for proven selective ablation of biological samples

Eye-safe Class 1 laser alignment

Enhanced operational lifetime characteristics to minimize operating costs

Fully sealed interlocked optical path with pressurized purge and multi-position mirrors for 5× mirror lifetime

Software controlled, dual polarizers with geo configuration enabling superior birefringence measurements

Intuitive Chromium 3.0 software

Software controlled motorized dual cross-polarizers for both transmitted & coax lighting

HDIP Pulse-to-pulse highly reproducible analytical data

High precision analytical data irrespective of single pulse response (SPR) speed

CETAC Analyte Excite+ Excimer LA System

Best value in excimer laser ablation systems

Ultra-short 193 nm wavelength

Ultrashort < 5 ns

Surplus fluence ablates all materials

Sealed Gas Cabinet

Optical homogenization of the laser beam for uniform flat ablations

Synchronized “fire-on-the-fly” lasing for the ultimate depth control during ablation

100 × 100 mm stage travel as standard

Independent video and lasing optical element for optimal viewing and crater quality

Aperture imaged spots ranging from 1.0 μm to >150 μm

30 apertures as standard; custom masks available

HelEx II Active 2-Volume Cell Compatible

CETAC Excite Pharos Femtosecond System

Light Conversion Pharos Laser Source

1028 nm, 257 nm & 206 nm wavelengths

Pulse duration < 290 fs

Pulse energy up to 1.5 mJ

Flexibility in repetition rate: 1 Hz to 1 kHz in 1 Hz increments

Only 1 refractive optic for minimal pulse stretching

Independent beam paths for each wavelength

Independent video and lasing optical element for optimal viewing and crater quality

Continuously variable 1 – 65 µm spot size

HelEx II active 2-volume ablation cell compatible

ARIS fast washout compatible

Fully integrated chiller to minimize footprint

CETAC Analyte HE High Energy Excimer LA System

Ultra-short 193 nm wavelength

Up to 50 J/cm2 fluence ablates all materials, including quartz and fluorite

Optical homogenization of the laser beam for uniform flat ablations

Sealed gas cabinet

100 × 100 mm stage travel as standard, 150 x 150 travel option available

Synchronized “fire-on-the-fly” lasing for the ultimate depth control during ablation

Independent video and lasing optical element for optimal viewing and crater quality

Aperture imaged spots ranging from 2 μm to 175 μm

30 apertures as standard; custom masks available

HelEx II active 2-volume ablation cell as standard

CETAC LSX-213 G2+ System

Frequency quintupled 213 nm Q-switched Nd:YAG laser with > 4 mJ source pulse energy and < 5 ns pulse width

< 3% pulse to pulse stability throughout

Flat top energy profile

Mechanically and thermally isolat ed laser beam delivery and viewing path for maximum stability

Variable output energy and variable pulse repetition frequency (1 – 20 Hz)

Variable laser spot size (4 – 200 μm)

Fully sealed laser head with user changeable flashlamp

Computer controlled, continuously adjustable parfocal video microscope (2.6x – 32.5x optical zoom range)

Wide field of view (> 6 mm) at high optical resolution (< 2 µm)

High intensity LED lighting arrays

Motorized rotating polarizer

Open Architecture for maximum flexibility

HelEx II Active 2-Volume Cell Compatible

High precision XY stages (0.16 µm/step)

Get Your Quote And Start Today